Sensitization testing is used to assess the potential of chemicals and medical devices to cause a delayed hypersensitivity reaction following a single or repeated exposure to the body. Sensitization is one of the three most common biocompatibility tests required to ensure the safety of medical devices.
"Tests for irritation and skin sensitization", part ten of the Biological evaluation of medical devices standards (ISO 10993-10), gives out the general considerations that should be taken into account when evaluating the potential of inducing sensitizing of a medical device. It outlines the procedure of studies to assess the potential of medical devices and their constituent materials to induce irritation and skin sensitization.
General Procedures of the Sensitization Test
- Exposing the animals to the test materials or extracts across multiple induction phases and a single challenge phase;
- Observing the challenge sites for about 24 and 48 hours after the removal of the test materials or extracts and evaluating skin sensitization reactions.
Sensitization reactions are noted by observing erythema and/or edema as it interacts with the body's immune system.
STEMart offers several methods as in vivo and in vitro assays for sensitization biocompatibility testing following the biocompatibility guidelines modified for medical devices. The testing is designed and performed based on the route of exposure to the body and acceptance of the notified body.
Sensitization Testing Capabilities
Two types of tests have been developed: an adjuvant test in which sensitization is potentiated by the injection of Freund's Complete Adjuvant (FCA), and non-adjuvant tests.
LLNA studies the induction period of skin sensitization and delivers quantitative data for dose-response assessment. LLNA is an in vivo method that will not eliminate the use of animals but have the potential to reduce the number of animals required for this purpose and cause less pain and distress. LLNA does not require that challenge-induced dermal hypersensitivity reactions be elicited or the use of an adjuvant.
Fig. 1 The local lymph node assay method. (Gerberick, 2000)
The GPMT is an in vivo test to screen for substances that cause human skin sensitization. The test animals are put together with an adjuvant, exposed intradermally to the test articles to enhance the immune reaction.
The Buehler Assay is a non-adjuvant in vivo test to screen for substances that cause human skin sensitization (i.e. allergens). In the test, Guinea pigs are exposed to a high dose of the substance, followed by a challenge dose, which is the highest dose that does not cause irritation.
- In Vitro Sensitization
We offer three-tiered in vitro skin sensitization tests: Direct Peptide Reactivity Assay (DPRA); ARE-Nrf2 Luciferase Test (KeratinoSens); Human Cell Line Activation Test (hCLAT)
If you have additional questions about Sensitization Testing or would like to find out more about our services, please feel free to contact us.
Reference
- Gerberick, G. Frank, et al. "Local lymph node assay: validation assessment for regulatory purposes." American Journal of Contact Dermatitis 11.1 (2000): 3-18.
Article source: https://article-realm.com/article/Health-Fitness/54411-Sensitization-ISO-10993-10.html
Comments
Reviews
Most Recent Articles
- Jun 5, 2026 Receive Life-Saving Transit at Panchmukhi Air Ambulance in Patna 24/7 by Panchmukhi Train Ambulance Services
- Jun 4, 2026 To Hire a Reliable Medical Transport Contact Panchmukhi Air Ambulance in Guwahati by Panchmukhi Train Ambulance Services
- Jun 4, 2026 Have a Relaxing Medical Transfer with Panchmukhi Air Ambulance in Kolkata by Panchmukhi Train Ambulance Services
- Jun 4, 2026 Choose the Authentically Organized Panchmukhi Train Ambulance in Patna and Delhi by Panchmukhi Train Ambulance Services
- Jun 2, 2026 Any Possibilities of Trouble are Ruled Out at Panchmukhi Air Ambulance Service in Mumbai by Panchmukhi Train Ambulance Services
Most Viewed Articles
- 36849 hits Familiarize The Process Of SEO by Winalyn Gaspelos
- 9229 hits NBC Sports Gold Activate by Tatiana Garcia
- 3592 hits Fix “unlicensed product” activation error during Office setup by Sophia Williams
- 3467 hits Get Solution of Hp Printer Offline Errors on Windows and Mac by shubhi gupta
- 3176 hits Very Important Ergonomic Office Furniture Brand You Should Know About by neck
Popular Articles
In today’s competitive world, one must be knowledgeable about the latest online business that works effectively through seo services....
80669 Views
Are you caught in between seo companies introduced by a friend, researched by you, or advertised by a particular site? If that is...
36849 Views
Walmart is being sued by a customer alleging racial discrimination. The customer who has filed a lawsuit against the retailer claims that it...
29356 Views
Facebook, the best and most used social app in the world, has all the social features you need. However, one feature is missing. You cannot chat...
23153 Views
If you have an idea for a new product, you can start by performing a patent search. This will help you decide whether your idea could become the...
14333 Views
A membrane contactor is a device that enables the transfer of components between two immiscible phases, typically a gas and a liquid, through a...
10221 Views
Moving becomes easy when you have the right moving accessories. These moving accessories help secure and protect your item by ensuring that no harm...
10185 Views
HP Officejet Pro 8600 is the best printer to fulfill the high-volume printing requirements. It supports the top quality printer which can satisfy...
10079 Views
Moving from one state, city, or even to a whole different county, is something that is either dictated by choice or circumstance. This is because,...
9245 Views
Statistics
| Members | |
|---|---|
| Members: | 16447 |
| Publishing | |
|---|---|
| Articles: | 77,618 |
| Categories: | 202 |
| Online | |
|---|---|
| Active Users: | 522 |
| Members: | 6 |
| Guests: | 516 |
| Bots: | 13318 |
| Visits last 24h (live): | 1352 |
| Visits last 24h (bots): | 33037 |